Description
The Strograph AE Film is fully automatic tensile tester for plastic films employing latest mechatronics technology. It is designed incorporating specimen tray and conveyor mechanism for transporting specimens. As regards functions and configuration of this machine, it consists of a specimen storage unit, specimen thickness measuring unit, specimen conveyor unit, testing unit, specimen mounting/dismounting unit and data processing unit. By simply loading specimens in the tray of specimen storage box, it automatically perform tests continuously at specified speed. On the other hand, load and elongation of specimen pulled under specified test conditions are converted to electric signals, the data are processed by the personal computer and are printed out.
SPECIFICATIONS
Main unit | |
Tensile speed | 0.5 to 500mm/min. (19 steps) |
Return speed | Max. 1500mm/min. |
Speed accuracy | ±0.5% |
Effective stroke | Approx. 650mm (Approx. 850mm optional) |
Measurement unit | |
Load cell | Max. 500N |
Load range | Range-less (Equivalent with x1 to x100) |
Accuracy | ±1.0% (In the range 1/1 to 1/500 of load cell related capacity) |
Zeroing | Automatic |
Sag correction | Automatic |
Pneumatic chuck | |
Face size | W30 x H12mm |
Capacity | 500N |
Thickness measurement section | |
Thickness measurement gauge | Digital type |
Resolution | 1/1000mm |
Accuracy | ±3/1000mm |
Measurement points | 3 points, within gauge length |
Measurement anvil | Ø5mm |
Extensometer | |
Method | Contact type |
Gauge length | 50mm |
Tracking speed | Max. 500mm/min |
Effective stroke | Approx. 500mm |
Specimen tray | |
Number of specimens | Max. 100 specimens (n=5 x 20 trays)
Max. 250 specimens (n=5 x 50 trays) optional |
Kind of tray
|
To be selected upon order.
|
Data processing unit | |
Configuration | Personal computer, LCD monitor, Ink-jet printer, Data processing software |
Setting parameters | Date, Operator, Temperature, Humidity, Test condition, Lot, Grade |
Data processing parameters | Max. stress, Max elongation, Yield stress, Yield elongation, Tensile modulus, Max value, Minimum value, Average, Standard deviation |
Utilities | |
Power supply | Single-phase, 50/60Hz, AC100V, 1.5kVA |
Compressed air supply | 0.5MPa, Approx. 40L/min. |
Dimensions | Main unit: Approx. W800 x D760 x H2240mm
Data processing unit: Approx. W800 x D640 x H1260mm |
Net weight | Main unit: Approx. 220kg |
Related standards | ISO 527-3, JIS Z 1702 |
Related standards
ISO 527-3
JIS Z 1702